Analytic scale ABS-N / ABJ-NM / ACS / ACJ
inkl. MwSt. zzgl. Versandkosten
- Artikel-Nr.: 4-50-20-02
The bestseller among the analysis scales. Built with a single point load cell. Also available as a calibrated version.
The ABJ and ACJ versions have an internal automatic adjustment system for temperature changes > 2°C and timed every 24 hours. This guarantees a high level of accuracy and makes the scale mobile. Location independence is the key word.
The variants ABS-N and ACS have the adjustment program CAL for adjusting the accuracy with an external test weight. The ACS is identical to the ABS. The ACJ is identical to the ABJ, but has an integrated data interface RS232 and USB.
With the combined TARA/PRINT function, a convenient recipe and documentation is possible. The mixture components of the recipe are automatically numbered and printed with number / weight value. The identification number of each scale is freely programmable. This 4-digit number makes it easy to assign the scale. Of course, this number is printed in the adjustment log.
An automatic data output to the PC/printer takes place after each standstill of the balance. You benefit from the built-insingle-cell load cell at a glance:
Ø Fully automatic production of the load cell from one piece
Ø Stable temperature behaviour
Ø Short settling time: Stable weighing values within approx. 3 seconds under laboratory conditions
Ø High mechanical robustness
Ø High corner load safety
The safety hood is included in all scales.
specifications
Ø Dimensions housing (W/D/H): 210 x 340 x 325 mm
Ø Dimensions windscreen (W/D/H): 201 x 220 x 256mm
Ø Height-adjustable feet for leveling the balance
Ø Housing material: Plastic
Ø Dragonfly for aligning the balance
Ø Material of the weighing plate:stainless steel
Ø Weighingarea: Around 91 mm
Ø Wägeraum (B/T/H): 174 / 162 / 227 mm
Ø Ziffernhöhe Display: 14 mm, hintergrundbeleuchtet
Ø Input voltage: 100 - 265V; 50-60Hz; 2.0A
Ø Power supply included (UK, US,EURO, CH)
functions
Ø Prozentbestimmung
Ø Stand-by function
Ø Summenspeicherfunktion
Ø Weighing with tolerance range
Ø Zählfunktion
Wägeeigenschaften
Ø Warm-up time: 4 hours
Ø Resolution: 820.000 parts
Ø Settling time under laboratory conditions: 3 s
Ø Recommended adjustment weight: Accuracy class E2
Ø Wägeeinheiten: mg, g, ct
Ø Wägesystem: Kraftkompensation
Ø Humidity(max): 85%
Ø Humidity (min): 20%
Ø Ambient term peraturerange: 10° C to 30° C
Ø Dimensions packaging (W/T/H): 390 / 560 / 530 mm
Ø Net Weight: 6 kg
The table lists the different models:
Analysis- | ||||||
scales | ||||||
ADB/ADJ | ||||||
overview | ||||||
Weighing-rich | Readability | Reprodu-zability | linearity | calibration | Option DAkkS | |
|
|
|
|
|
|
|
ABS 80-4N | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABS 120-4N | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABS 220-4N | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABS 320-4N | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABJ 80-4NM | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABJ 120-4NM | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABJ 220-4NM | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ABJ 320-4NM | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ACS 80-4 | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ACS 100-4 | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ACS 200-4 | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ACS 300-4 | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| And |
|
|
|
|
|
|
|
ACJ 80-4M | 82 g | 0,1 mg | 0,2 mg | 0,3 mg | and (1 mg) | And |
|
|
|
|
|
|
|
ACJ 100-4M | 120 g | 0,1 mg | 0,2 mg | 0,3 mg | and (1 mg) | And |
|
|
|
|
|
|
|
ACJ 200-4M | 220 g | 0,1 mg | 0,2 mg | 0,3 mg | and (1 mg) | And |
|
|
|
|
|
|
|
ACJ 300-4M | 320 g | 0,1 mg | 0,2 mg | 0,3 mg | and (1 mg) | And |
|
|
|
|
|
|
|
accessories
The analysis scale makes the well-thought-out accessories even better. This simplifies work steps and makes documentation easy.
Ø Data interface RS-232, incl. interface cable
Ø Occupational safety hood, scope of delivery 5 pieces
Ø Ionizer for neutralizing electrostatic charge
Ø Set for the density determination of liquids and solids
Ø Staubschutzhaube
Ø RS-232/Ethernet adapter for connecting force measuring instruments
Ø RS-232/Bluetooth-Adapter
Ø RS-232/W-LAN-Adapter
Download
Take all the information with you - in the download area:
Ø Operating Instructions (german)
Ø User manual
Ø Short Operating Instructions (german)
Ø brochure
Ø Menüübersicht
Ø Musterkalibrierschein
Ø Declaration
Technische Daten
- Ø Abmessungen Gehäuse (B/T/H): 210 x 340 x 325 mm
- Ø Abmessungen Windschutz (B/T/H): 201 x 220 x 256 mm
- Ø Höhenverstellbare Füße zum Nivellieren der Waage
- Ø Gehäusematerial: Kunststoff
- Ø Libelle zum Ausrichten der Waage
- Ø Material der Wägeplatte: Edelstahl
- Ø Wägefläche: Rund 91 mm
- Ø Wägeraum (B/T/H): 174 / 162 / 227 mm
- Ø Ziffernhöhe Display: 14 mm, hintergrundbeleuchtet
- Ø Eingangsspannung: 100 – 265V; 50-60Hz; 2.0A
- Ø Netzteil im Lieferumfang enthalten (UK, US, EURO, CH)
- Funktionen
- Ø Prozentbestimmung
- Ø Stand-by-Funktion
- Ø Summenspeicherfunktion
- Ø Wägen mit Toleranzbereich
- Ø Zählfunktion
Wägeeigenschaften
- Ø Anwärmzeit: 4 Stunden
- Ø Auflösung: 820.000 Teile
- Ø Einschwingzeit unter Laborbedingungen: 3 s
- Ø Empfohlenes Justiergewicht: Genauigkeitsklasse E2
- Ø Wägeeinheiten: mg, g, ct
- Ø Wägesystem: Kraftkompensation
- Ø Luftfeuchtigkeit (max): 85 %
- Ø Luftfeuchtigkeit (min): 20 %
- Ø Umgebungstermperaturbereich: 10° C bis 30° C
- Ø Abmessungen Verpackung (B/T/H): 390 / 560 / 530 mm
- Ø Nettogewicht: 6 kg
Die Tabelle führt die verschiedenen Modelle auf:
Analyse- | ||||||
Waage | ||||||
ADB/ADJ | ||||||
Übersicht | ||||||
Wägebe-reich | Ables-barkeit | Reprodu-zierbar-keit | Linearität | Eichung | Option DAkkS | |
|
|
|
|
|
|
|
ABS 80-4N | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABS 120-4N | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABS 220-4N | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABS 320-4N | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABJ 80-4NM | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABJ 120-4NM | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABJ 220-4NM | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ABJ 320-4NM | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ACS 80-4 | 82 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ACS 100-4 | 120 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ACS 200-4 | 220 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ACS 300-4 | 320 g | 0,1 mg | 0,2 mg | 0,3 mg |
| ja |
|
|
|
|
|
|
|
ACJ 80-4M | 82 g | 0,1 mg | 0,2 mg | 0,3 mg | ja (1 mg) | ja |
|
|
|
|
|
|
|
ACJ 100-4M | 120 g | 0,1 mg | 0,2 mg | 0,3 mg | ja (1 mg) | ja |
|
|
|
|
|
|
|
ACJ 200-4M | 220 g | 0,1 mg | 0,2 mg | 0,3 mg | ja (1 mg) | ja |
|
|
|
|
|
|
|
ACJ 300-4M | 320 g | 0,1 mg | 0,2 mg | 0,3 mg | ja (1 mg) | ja |
|
|
|
|
|
|
|
Zubehör
Noch besser macht die Analysewaage das durchdachte Zubehör. Damit können Arbeitsschritte vereinfacht und die Dokumentation einfach gestaltet werden.
- Ø Datenschnittstelle RS-232, inkl. Schnittstellenkabel
- Ø Arbeitsschutzhaube, Lieferumfang 5 Stück
- Ø Ionisator zum Neutralisieren elektrostatischer Aufladung
- Ø Set zur Dichtebestimmung von Flüssigkeiten und Feststoffen
- Ø Staubschutzhaube
- Ø RS-232/Ethernet-Adapter zur Anbindung von Kraftmessinstrumenten
- Ø RS-232/Bluetooth-Adapter
- Ø RS-232/W-LAN-Adapter
Download
Alle Informationen einfach mitnehmen – im Downloadbereich:
- Ø Betriebsanleitung (deutsch)
- Ø User manual
- Ø Kurzbetriebsanleitung (deutsch)
- Ø Prospekt
- Ø Menüübersicht
- Ø Musterkalibrierschein
- Ø Konformitätserklärung